| Sign In | Join Free | My futurenowinc.com |
|
Brand Name : KingPo
MOQ : 1
Place of Origin : China
Certification : ISO 17025 Calibration certificate
Price : To be quoted
Packaging Details : safety box
Delivery Time : 25~30 working days
Payment Terms : 100% TT in advance
Supply Ability : 3~5 units per month
spec : 20V10A
channel : 4/8/customized
Input power : AC 220V ±10% / 60Hz
Input active power : 2228W
resolution ratio : AD:16bit;DA:12bit
Input impedance : ≥1MΩ
20V 10A EV Battery Testing Equipment With Calibration Certificate
20V10A Battery Charge and Discharge system
BTS-20V10A Battery Testing System , Battery Testing Equipment With Calibration Certificate
Technical Parameter:
|
| BTS-20V10A Battery tester |
| ||||||||||||||||||
| Model Number: | BTS- | 20 | V | 10 | A | Battery tester | Material code: | CT-3008 | -20V10A | - | NA | - | P | |||||||
| items | Parameter | |||||||||||||||||||
| Input power | AC 220V ±10% / 60Hz | |||||||||||||||||||
| Input active power | 2228 | W | ||||||||||||||||||
| resolution ratio | AD:16bit;DA:12bit | |||||||||||||||||||
| Input impedance | ≥1MΩ | |||||||||||||||||||
| voltage | Constant voltage range | 100mV~20V |
| |||||||||||||||||
| Minimum discharge voltage | 2.5V | |||||||||||||||||||
| accuracy | ± 0.1% of FS | |||||||||||||||||||
| stability | ± 0.1% of FS | |||||||||||||||||||
| current | Output range/channel | 50mA~10A | ||||||||||||||||||
| accuracy | ± 0.1% of FS | |||||||||||||||||||
| Constant voltage cut-off current | 0.02A | |||||||||||||||||||
| stability | ± 0.1% of FS | |||||||||||||||||||
| power | Output range/channel | 200W | ||||||||||||||||||
| stability | ± 0.2% of FS | |||||||||||||||||||
| time | Current response time | maximum current rising time:20ms | ||||||||||||||||||
| working step time range | ≤(365*24)h/working step | Time format00:00:00(h,min,s) | ||||||||||||||||||
| Data record | Record data conditions | Minimum sampling time:1s | ||||||||||||||||||
| Minimum sampling voltage:40mV | ||||||||||||||||||||
| Minimum sampling current:20mA | ||||||||||||||||||||
| Record frequency | 1Hz | |||||||||||||||||||
| Charge | Charge mode | constant-current charge,constant-voltage charge,constant voltage and current charge | ||||||||||||||||||
| cut-off conditions | Voltage,current,relative time,capacity,-△;V | |||||||||||||||||||
| discharge | Discharge mode | constant current discharge, constant watt discharge | ||||||||||||||||||
| cut-off conditions | Voltage,current,relative time,capacity,-△;V | |||||||||||||||||||
| cycle | Loop test range | 1~65535 times | ||||||||||||||||||
| Single cycle working steps | 254 | |||||||||||||||||||
| Loop nest | Nested loop function,max 3 layers | |||||||||||||||||||
| Protection | ● Data Protection | |||||||||||||||||||
| ● off-line test | ||||||||||||||||||||
| ● security conditions can be set including voltage upper/lower limit,current upper/lower limit and delay time | ||||||||||||||||||||
| ●anti reverse connection | ||||||||||||||||||||
| IP Protection Class | IP20 | |||||||||||||||||||
| Channel feature | constant current and voltage source ;double closed-loop; |
| ||||||||||||||||||
| Channel control mode | independent |
| ||||||||||||||||||
| Current/voltage detection sampling | four-wire connection |
| ||||||||||||||||||
| noise | <85dB |
| ||||||||||||||||||
| data base | MySQL centralized management of test datas |
| ||||||||||||||||||
| upper computer communication mode | TCP/IP |
| ||||||||||||||||||
| Data output mode | EXCEL2003,2010,TXT |
| ||||||||||||||||||
| Server disk Configuration | 500GB |
| ||||||||||||||||||
| Server operating system | Windows 7 |
| ||||||||||||||||||
| communication interface | ethernet |
| ||||||||||||||||||
| Working environment requirement |
| |||||||||||||||||||
| item | parameter |
| ||||||||||||||||||
| working temp. range | 0℃~40℃(within25±10℃,ensured accuracy:precision drift0.005% of FS /℃) |
| ||||||||||||||||||
| Storage temp. range | -10℃~50℃ |
| ||||||||||||||||||
| Working environment relative humidity range | ≤70% RH(no water vapor condensation) |
| ||||||||||||||||||
| Storage environment relative humidity range | ≤80% RH(no water vapor condensation) |
| ||||||||||||||||||
| Clamp specification and size |
| |||||||||||||||||||
| item | parameter |
| ||||||||||||||||||
| Clamp type | Polymer clamp |
| ||||||||||||||||||
| Pic |
|
|
|
| ||||||||||||||||
| Alligator clamp | Polymer clamp | cable feet clamp |
| |||||||||||||||||
| Pictures are for reference only,real objects shall prevail.Choose one |
| |||||||||||||||||||
| Cabinet size/unit(W*D*H)(mm) | 12U(19&”),600*600*740 |
| ||||||||||||||||||
| Equipment pic |
|
| ||||||||||||||||||
| Pictures are for reference only,real objects shall prevail. |
|
| ||||||||||||||||||
Hot Tags: 20V10A Battery Charge and Discharge system, China, manufacturers, suppliers, factory, custom, wholesale, Lateral Strain For Socket-outlets Teser, Electric Iron Drop Tester, Mandrel Test Device, IEC60068 Pendulum Hammer Test Apparatus, IPX3X4 Oscillating Tube Test Device, Ingress Protection Test Equipment
|
|
20V 10A EV Battery Testing Equipment With Calibration Certificate Images |